HT-803 digital temperature humidity controller with 0~100%RH relative humidity probe for mushroom, mini greenhouse, ventilator fan
HENGKO temperature and humidity control high precision RHT series sensor equipped with a sintered metal filter shell for large air permeability, fast gas humidity flow, and exchange rate. The shell is waterproof and will keep water from seeping into the body of the sensor and damaging it, but allows air to pass through so that it can measure the humidity (moisture) of the environment. It has been widely used in HVAC, consumer goods, weather stations, test & measurement, automation, medical, and humidifiers, and especially perform well in extreme environment like acid, alkali, corrosion, high temperature, and pressure.
HT-803 intelligent digital temperature and humidity controller is mainly used for electric power equipment (such as outdoor terminal boxes, high and low voltage control cabinets, box-type substations, circuit breaker mechanism boxes, instrument boxes, etc.) and other occasions that require automatic moisture removal, dew prevention, and temperature control. It can effectively prevent all kinds of accidents caused by humidity, dew, and high (low) temperature, and ensure the efficient and safe operation of automation operations.
This is a digital humidity controller with wide humidity measuring and control range.Humidification and Dehumidification modes can be set through the menu. These functions require relays.
Features:
Microcontroller based design.
Elegant appearance, easy to operate and compact in size.
Highly accurate and sturdy in operation.
Digital displaying of temperature, humidity and turning frequency.
Field proven Algorithm, tested successfully for various Hatchery Incubator control applications
Want more information or would like to receive a quote?
Click the Online Service button at the top right to contact our salespeople.
E-mail:
ka@hengko.com sales@hengko.com f@hengko.com h@hengko.com
HT-803 Digital temperature and humidity controller with sensor 0~100%RH relative humidity probe
Dehumidification Mode Example:
If you want a dehumidifiers to be turned on at 95% and turned off at 85%. Set the controller to Dehumidification mode, set target humidity to 85 and set differential value(humidity span) to 10. Once detected humidity is above 95%, the controller turns on dehumidifiers. Once detected humidity reaches 85%, the controller turns off dehumidifiers.
Humidification Mode Example:
If you want a humidifiers to be turned on at 60% and turned off at 80%. Set the controller to Humidification mode, set target humidity to 80 and set differential value(humidity span) to 20. Once detected humidity is below 60%, the controller turns on your humidifiers. Once detected humidity reaches 80%, the controller turns off the humidifiers.
Product Parameter
Power Supply
You have two supply voltages to choose from
ONE: 220V DC
TWO: 12V DC
WARM PROMPT
Humidity Sensor Mounting
For pedestal (rail) mounting, snap the humidity sensor probe onto the 35mm mounting rail or secure it to the mounting plate with screws. The sensor should be mounted in a location near the temperature and humidity controlled device.