High Temperature Humidity Transmitter Around 190℃ RS485 Modbus 4-20mA Output

High Temperature Humidity Transmitter Around 190℃ RS485 Modbus 4-20mA Output

Short Description:


  • Brand: HENGKO
  • Output Option: RS485 + 4-20mA / RS485 + 0-5v / RS485 + 0-10v
  • Temperature range: -40 ~ 190°C ( U-series) / -50 ~ 150°C ( W-series)/ -40 ~ 150°C ( S-series)
  • Dew point range: -60 ~ 80°C (U series ) / -60 ~ 80°C ( W-series ) / -80 ~ 80°C ( S-series )
  • Humidity range: 0 ~ 100%RH (recommended <95%RH)
  • Temperature accuracy: ±0.1°C (@20°C)
  • Humidity accuracy: ±2%RH (@20°C, 10~90%RH)
  • Dew point accuracy: ±2°C (± 3.6 °F) Td
  • Power supply: DC 10V ~ 30V
  • RS485 digital output: Temperature, humidity, dew point (read simultaneously)
  • Operating temperature: – 20℃ ~ +60℃, 0%RH ~ 95%RH (non-condensing)
  • Product Detail

    Product Tags

    HG808 Super High Temperature Humidity Transmitter

    The HG808 is an industrial-grade temperature, humidity, and dew point transmitter designed for harsh environments with high temperatures. In addition to measuring and transmitting temperature and humidity, the HG808 calculates and transmits the dew point, which is the temperature at which air becomes saturated with water vapor and condensation begins to form.

    Here’s a breakdown of the key features:

    • Temperature range: -40 ℃ to 190 ℃ (-40 °F to 374 °F)
    • Probe: The transmitter is equipped with a high-temperature probe that is waterproof and resistant to fine dust.
    • Output: The HG808 offers flexible output options for temperature, humidity, and dew point data:
      • Standard industrial interface RS485 digital signal
      • 4-20 mA analog output
      • Optional: 0-5v or 0-10v output
    • Display: The transmitter has an integrated display for viewing temperature, humidity, and dew point readings.
    • Connectivity: The HG808 can be connected to various industrial control systems, including:
      • On-site digital display meters
      • PLCs (Programmable Logic Controllers)
      • Frequency converters
      • Industrial control hosts

     Probe Option of HG808 Temperature Humidity Transmitter

     

    Product Highlights:

    ▪Integrated design, simple and elegant
    ▪Industrial grade ESD safety protection and power supply anti reverse connection design
    ▪Using waterproof, dustproof, and high-temperature resistant probes
    ▪Sensitive waterproof and anti fine dust high-temperature probe
    ▪Standard RS485 Modbus RTU communication protocol

    The ability to measure dew point makes the HG808 ideal for applications where moisture control is critical, such as:

    • HVAC systems
    • Industrial drying processes
    • Weather monitoring stations
     

    By measuring and transmitting all three values (temperature, humidity, and dew point), the HG808 provides a comprehensive picture of moisture conditions in harsh environments.

     

    HG808 Data Sheet Details

     

     

    Parameter Value
    Temperature range -40 ~ 190°C ( U-series) /  -50 ~ 150°C ( W-series)/ -40 ~ 150°C ( S-series)
    Dew point range -60 ~ 80°C (U series ) / -60 ~ 80°C (  W-series ) / -80 ~ 80°C ( S-series )
    Humidity range 0 ~ 100%RH (recommended <95%RH)
    Temperature accuracy ±0.1°C (@20°C)
    Humidity accuracy ±2%RH (@20°C, 10~90%RH)
    Dew point accuracy ±2°C (± 3.6 °F) Td
    Input and output  RS485 + 4-20mA / RS485 + 0-5v / RS485 + 0-10v 
    Power supply DC 10V ~ 30V
    Power consumption <0.5W
    Analog signal output  Humidity + Temperature / Dew point + Temperature (choose one of the two)
      4~20mA / 0-5V / 0-10V (choose one)
    RS485 digital output  Temperature, humidity, dew point (read simultaneously)
      Resolution: 0.01°C / 0.1°C optional
    Communication baud rate 1200、2400、4800、9600、19200、115200 can be set, default 9600 bps
    Acquisition frequency Fastest 1s response, others can be set according to PLC
    HG808 Dew Point Transmitter User Manual V1.1 9
    Byte format 8 data bits, 1 stop bit, no parity
    Pressure resistance 16 bar
    Operating temperature – 20℃ ~ +60℃, 0%RH ~ 95%RH (non-condensing)

     

    high temperature humidity transmitter with long screw metal probe display (2) high temperature humidity transmitter with long screw metal probe display high temperature humidity transmitter with long screw metal probe high temperature humidity transmitter with normal metal probe display high temperature humidity transmitter with short duct flange metal probe display

     

    0-5v Temperature Humidity Transmitter Wire Connect Diagram 0-10v Temperature Humidity Transmitter Wire Connect Diagram 4-20mA Temperature Humidity Transmitter Wire Connect Diagram functions of each color wire core connect diagram HG808 Humidity Transmitter

     

     

     

    HG808 Temperature Humidity Transmitter Series ( Order No. )

     
    N Picture Probe Output Display U Series W Series S Series
    1   1# Split Probe    (80mm) 4-20ma +RS485 No

    Humidity: -40~190°c

    Dew point: -60~80°c

    Relative humidity: 0-100%

    HG808-U1N4

    Humidity: -50~150°c

    Dew point: -60~80°c

    Relative humidity: 0-100%

    HG808-W1N4

    Humidity: -40~150°c

    Dew point: -80~80°c

    Relative humidity: 0-100%

    HG808-S1N4
    0-5V +RS485 HG808-U1N5 HG808-W1N5 HG808-S1N5
    0-10V +RS485 HG808-U1N1 HG808-W1N1 HG808-S1N1
    4-20ma +RS485 Yes HG808-U1Y4 HG808-W1Y4 HG808-S1Y4
    0-5V +RS485 HG808-U1Y5 HG808-W1Y5 HG808-S1Y5
    0-10V +RS485 HG808-U1Y1 HG808-W1Y1 HG808-S1Y1
    2   2# Split Probe     (170+40mm) 4-20ma +RS485 No HG808-U2N4 HG808-W2N4 HG808-S2N4
    0-5V +RS485 HG808-U2N5 HG808-W2N5 HG808-S2N5
    0-10V +RS485 HG808-U2N1 HG808-W2N1 HG808-S2N1
    4-20ma +RS485 Yes HG808-U2Y4 HG808-W2Y4 HG808-S2Y4
    0-5V +RS485 HG808-U2Y5 HG808-W2Y5 HG808-S2Y5
    0-10V +RS485 HG808-U2Y1 HG808-W2Y1 HG808-S2Y1
    3   3# Split Probe   (215+40mm) 4-20ma +RS485 No HG808-U3N4 HG808-W3N4 HG808-S3N4
    0-5V +RS485 HG808-U3N5 HG808-W3N5 HG808-S3N5
    0-10V +RS485 HG808-U3N1 HG808-W3N1 HG808-S3N1
    4-20ma +RS485 Yes HG808-U3Y4 HG808-W3Y4 HG808-S3Y4
    0-5V +RS485 HG808-U3Y5 HG808-W3Y5 HG808-S3Y5
    0-10V +RS485 HG808-U3Y1 HG808-W3Y1 HG808-S3Y1
    4   4# Duck Probe  (260mm) 4-20ma +RS485 No HG808-U4N4 HG808-W4N4 HG808-S4N4
    0-5V +RS485 HG808-U4N5 HG808-W4N5 HG808-S4N5
    0-10V +RS485 HG808-U4N1 HG808-W4N1 HG808-S4N1
    4-20ma +RS485 Yes HG808-U4Y4 HG808-W4Y4 HG808-S4Y4
    0-5V +RS485 HG808-U4Y5 HG808-W4Y5 HG808-S4Y5
    0-10V +RS485 HG808-U4Y1 HG808-W4Y1 HG808-S4Y1
    5   5# Duct Probe  (460mm) 4-20ma +RS485 No HG808-U5N4 HG808-W5N4 HG808-S5N4
    0-5V +RS485 HG808-U5N5 HG808-W5N5 HG808-S5N5
    0-10V +RS485 HG808-U5N1 HG808-W5N1 HG808-S5N1
    4-20ma +RS485 Yes HG808-U5Y4 HG808-W5Y4 HG808-S5Y4
    0-5V +RS485 HG808-U5Y5 HG808-W5Y5 HG808-S5Y5
    0-10V +RS485 HG808-U5Y1 HG808-W5Y1 HG808-S5Y1

     

    Applications for Extreme Environments

    Industrial processes often involve extreme temperatures and humidity levels. Regular transmitters can’t handle these harsh conditions. Here’s a breakdown of applications where high-temperature and humidity transmitters (operating over 200°C and down to -50°C) are crucial:

    High-Temperature Applications (Over 200°C):

    • Industrial Ovens and Furnaces: Monitoring temperature and humidity is vital in curing processes like painting, drying ceramics, and heat treating metals. Precise control ensures product quality and prevents defects.
    • Power Generation: Humidity measurement in power plants helps prevent corrosion in turbines and other equipment exposed to high temperatures and steam.
    • Chemical Processing: Accurate temperature and humidity data is essential for safe and efficient chemical reactions in reactors, dryers, and pipelines. Deviations can lead to hazardous situations or product contamination.
    • Semiconductor Manufacturing: Creating microchips involves tightly controlled environments with high temperatures and low humidity. Transmitters ensure proper conditions for sensitive processes like photolithography and etching.
    • Glass Manufacturing: Glass production requires precise temperature and humidity control during melting, blowing, and annealing. Transmitters help maintain consistent glass quality and prevent defects.

    Low-Temperature Applications (Down to -50°C):

    • Cold Storage Facilities: Monitoring temperature and humidity in freezers and cold warehouses helps maintain optimal conditions for food preservation and prevent spoilage.
    • Cryogenic Applications: Extremely low temperatures are used in research and industrial processes like superconductivity and liquefied natural gas (LNG) storage. Transmitters ensure safe handling and prevent equipment damage from ice formation.
    • Climate Monitoring: These transmitters are valuable tools for weather stations in extreme cold environments like the Arctic or high mountain regions. They provide accurate data for climate research and weather forecasting.
    • Aerospace Industry: Testing aircraft components for functionality in frigid conditions requires precise temperature and humidity control. Transmitters simulate real-world scenarios and ensure aircraft safety.
    • Wind Turbine Icing: Detecting and measuring ice formation on wind turbine blades is crucial for safe operation. Transmitters help prevent blade damage and power generation loss in cold climates.

     

    Send your message to us:

    Write your message here and send it to us


  • Previous:
  • Next:

  • Related Products